| Protocol |
| This value determine the charging protocol on the internal isdn ports. You have three options here: Keypad protocol - Charge data is transferred such that it can be displayed directly by the terminal device. Functional protocol - Charge data is transferred with binary encoding and must be decoded by the terminal device. Both - Both of these protocols are recognized (default settings for the PABX system. Enumerations: - keypad-and-functional (1)
- no-keypad (2)
- no-functional (3)
|
| Frequency |
| This value determine the frequency of the charge pulse for analog extensions Enumerations: - no (1)
- f12khz (2)
- f16khz (3)
|
| IncomingCall |
| You can define whether acquisition is to be made for all connection (1), or only when a project number is input (2). Enumerations: |
| Multiplier |
| Charge rate multiplier |
| Exponent |
| Charge rate exponent. |
| CurrencyName |
| This name will be displayed at the extension. Range: 0 to 3 |
| ExtensionIndex |
| You can define an extension index at which internal telephone the communication data overflow is to be signaled per uus1 message. Range: 0 to 65535 |
| HiddenDigitsCountA |
| You can enter the number of hidden digit positions for incoming calls. The positions (numbers) are concealed from right to left (from the end of the number). -1 = hide all |
| HiddenDigitsCountB |
| You can enter the number of hidden digit positions for outcoming calls. The positions (numbers) are concealed from right to left (from the end of the number). -1 = hide all |